Measure feeder mass flow from a timed catch test. Enter net collected kilograms, elapsed minutes and the recipe feed-rate setpoint.

What this calculator does

  • Measure feeder mass flow from a timed catch test.

Formula used

  • Measured rate = Collected mass × 60 ÷ Test minutes
  • Rate error = Measured rate − Required rate
  • Target catch = Required rate × Test minutes ÷ 60

Inputs explained

  • Collected Feed Mass: Net catch weight from the timed feeder test.
  • Catch Test Duration: Elapsed time across the complete catch test.
  • Required Feed Rate: Recipe mass-flow setpoint for the tested operating condition.

How to use the result

  • Best suited to feeder catch tests, recipe rate verification.
  • One average catch does not establish short-term flow stability.

Common questions

  • Should the container weight be included? No. Tare the container or subtract its empty mass.
  • Can I sample during hopper refill? Include refill only when the test is intended to represent that operating phase; record the phase with the result.
  • Is this dosing accuracy? It is average mass flow. Compare individual batch doses separately when batch accuracy is the question.
  • Does a matching average prove stable flow? No. Opposing flow excursions can cancel in a long catch test.