Weighing, Dosing & Loss-in-Weight Feeding calculator

Loss-In-Weight Catch Test Calibration Calculator

Compare a loss-in-weight controller total with an independent catch weight. Enter matched indicated mass, reference mass and the allowed indication error.

What this calculator does

  • Compare a loss-in-weight controller total with an independent catch weight.

Formula used

  • Indication error = Indicated mass − Reference catch
  • Indication error % = Indication error × 100 ÷ Reference catch
  • Reference-to-indicated ratio = Reference catch ÷ Indicated mass
  • Error margin = Allowed error % − Abs(Indication error %)

Inputs explained

  • Controller Indicated Discharge: Integrated discharge mass indicated during the timed catch.
  • Reference Net Catch Mass: Net catch weight from an independently checked balance.
  • Allowed Indication Error: Maximum absolute error from your calibration acceptance procedure.

How to use the result

  • Best suited to feeder calibration checks, controller total verification.
  • The ratio is not a universal calibration-factor update or speed correction.

Common questions

  • Can I multiply every calibration setting by this ratio? No. Manufacturers define calibration factors differently; follow the specific controller procedure.
  • Why use the caught mass as the denominator? It is the independent reference against which the controller indication is being checked.
  • Should refill periods be included? Use the test procedure specified for the feeder, and document whether the catch includes refill operation.
  • Does one catch establish calibration across the range? No. Repeat checks at the required rates and operating conditions in your calibration procedure.

Last reviewed 2026-10-12.